For information on how to unsubscribe, as well as our privacy practices and commitment to protecting your privacy, check out our Privacy Policy. Eclipse Business Media respects your privacy. Gas Chromatography. Like for all other chromatographic techniques, a mobile and a stationary phase are required for this technique. Most analytical gas chromatographs use capillary columns, where the stationary phase coats the walls of a small-diameter tube directly i.
In the example above, compound X interacts stronger with the stationary phase, and therefore lacks behind compound O in its movement through the column. As a result, compound O has a much shorter retention time than compound X. Which factors influence the separation of the components? Vapor pressure The boiling point of a compound is often related to its polarity see also polarity chapter. The lower the boiling point is, the higher the vapor pressure of the compound and the shorter retention time usually is because the compound will spent more time in the gas phase.
That is one of the main reasons why low boiling solvents i. The temperature of the column does not have to be above the boiling point because every compound has a non-zero vapor pressure at any given temperature, even solids. That is the reason why we can smell compounds like camphor 0. However, their vapor pressures are low compared to liquids i.
The polarity of components versus the polarity of stationary phase on column If the polarity of the stationary phase and compound are similar, the retention time increases because the compound interacts stronger with the stationary phase. Thermal modulators achieve this using temperature to trap and then release the molecules, flow modulators collect the effluent, compress and flush the molecules onto the second column.
Cuts are taken throughout the run, usually every 1 to 10 seconds. Separation on the second column should be achieved before the next cut is introduced. This fast separation is achieved by using a short, narrow second column, usually m of 0. GC is a widely used technique across most industries. It is used for routine analysis through to research, analysing a few to many hundreds or thousands with GC x GC of compounds in many different matrices, from solids to gases.
It is a robust technique and is easily hyphenated to other techniques including mass spectrometry. Thermally labile compounds can degrade in a hot GC, therefore cold injection techniques and low temperatures should be used to minimize this. More polar analytes can become stuck or lost in the GC, therefore the system should be deactivated and well-maintained or these analytes derivatized.
The most common problem in GC is leaks. The mobile phase is a gas and flows throughout the system, therefore the correct installation of parts and consumables is important along with regular leak checking. Activity is another issue for more polar analytes, especially those at trace levels. Silanol groups on the glass liners and column, and also a build-up of dirt in the system can cause tailing peaks, irreversible adsorption or catalytic breakdown.
The inlet is the area that causes most problems as it is here the sample is injected, vaporized and transferred into the GC column. Therefore, regular inlet maintenance along with using the correct consumables, for example a deactivated inlet liner, is important to keep the instrument trouble-free. What is gas chromatography? It can be used in many different fields such as pharmaceuticals, cosmetics and even environmental toxins.
Since the samples have to be volatile, human breathe, blood, saliva and other secretions containing large amounts of organic volatiles can be easily analyzed using GC. Knowing the amount of which compound is in a given sample gives a huge advantage in studying the effects of human health and of the environment as well.
Air samples can be analyzed using GC. Most of the time, air quality control units use GC coupled with FID in order to determine the components of a given air sample. Although other detectors are useful as well, FID is the most appropriate because of its sensitivity and resolution and also because it can detect very small molecules as well. This method be applied to many pharmaceutical applications such as identifying the amount of chemicals in drugs.
Moreover, cosmetic manufacturers also use this method to effectively measure how much of each chemical is used for their products. Some application, HETP concepts is used in industrial practice to convert number of theoretical plates to packing height. Introduction In early s, Gas chromatography GC was discovered by Mikhail Semenovich Tsvett as a separation technique to separate compounds.
Instrumentation Sample Injection A sample port is necessary for introducing the sample at the head of the column. Figure 1: A cross-sectional view of a microflash vaporizer direct injector. Carrier Gas The carrier gas plays an important role, and varies in the GC used. Figure 3. Gas Recommendations for Packed Columns. Column Oven The thermostatted oven serves to control the temperature of the column within a few tenths of a degree to conduct precise work.
The effect of column temperature on the shape of the peaks. Open Tubular Columns and Packed Columns Open tubular columns, which are also known as capillary columns, come in two basic forms. Figure 4. Properties of gas chromatography columns. Figure 5. Computer Generated Image of a FSWC column specialized to withstand extreme heat Different types of columns can be applied for different fields. Detection Systems The detector is the device located at the end of the column which provides a quantitative measurement of the components of the mixture as they elute in combination with the carrier gas.
Table 7: Typical gas chromatography detectors and their detection limits. Figure 8. Mass Spectrum of Water. Figure 9. Figure Schematic of a typical flame ionization detector.
Thermal Conductivity Detectors Thermal conductivity detectors TCD were one the earliest detectors developed for use with gas chromatography. Schematic of thermal conductivity detection cell. Electron-capture Detectors Electron-capture detectors ECD are highly selective detectors commonly used for detecting environmental samples as the device selectively detects organic compounds with moieties such as halogens, peroxides, quinones and nitro groups and gives little to no response for all other compounds.
Schematic of an electron-capture detector. Atomic Emission Detectors Atomic emission detectors AED , one of the newest addition to the gas chromatographer's arsenal, are element-selective detectors that utilize plasma, which is a partially ionized gas, to atomize all of the elements of a sample and excite their characteristic atomic emission spectra.
Instrumentation The components of the Atomic emission detectors include 1 an interface for the incoming capillary GC column to induce plasma chamber,2 a microwave chamber, 3 a cooling system, 4 a diffration grating that associated optics, and 5 a position adjustable photodiode array interfaced to a computer.
Schematic of atomic emission detector. GC Chemiluminescence Detectors Chemiluminescence spectroscopy CS is a process in which both qualitative and quantitative properties can be be determined using the optical emission from excited chemical species. Schematic of a GC Chemiluminescence Detector.
Photoionization Detectors Another different kind of detector for GC is the photoionization detector which utilizes the properties of chemiluminescence spectroscopy. Instrumentation Figure Schematic of a photoionization detector Limitations Not suitable for detecting semi-volatile compounds Only indicates if volatile organic compounds are presents.
High concentration so methane are required for higher performance. Frequent calibration are required. Units of parts per million range Enviromental distraction, especially water vapor. Strong electrical fieldsRapid variation in temperature at the detector and naturally occurring compounds may affect instrumental signal. Applications Gas chromatography is a physical separation method in where volatile mixtures are separated.
A is the "Eddy-Diffusion" term and causes the broadening of the solute band. B is the "Longitudinal diffusion" term whereby the concentration of the analyte, in which diffuses out from the center to the edges.
This causes the broadering of the analyte band. C is the "Resistance to Mass Transfer " term and causes the band of the analyte broader. References Skoog, D. Principles of Instrumental Analysis. Krugers, J. Instrumentation in Gas Chromatography.
Centrex Publishing Company-Eindhoven, Netherlands, Hubschmann, H. Scott, R.